Resources:
Cut Sheet
CAD Drawings 2 zone.dwg
CAD Drawings .pdf
CAD Drawings 4 zone.dwg
CAD Drawings .pdf
Physical Specifications:
Durable housing and waterproof epoxy construction
Width: 3 1/4" (9.5 cm)
Height: 2 7/8" (7.3 cm)
Depth: 1" (2.5 cm)
Wire Length: 48" (122 cm)
Model:
ACC-ADP-002, 2 Zones
ACC-ADP-004, 4 Zones
| Home > Products > Controllers > 2/4 Zone Adapters
2/4 Zone Adapters
For New Installations of the 2-Wire System
Acclima 2 and 4-zone Adapters are used to connect 24 volt ac solenoid valves and relays to the Acclima 2-wire system. They are designed to be installed in valve boxes or underground wiring boxes where they can adapt any 24 volt ac solenoid valve or pump-start relay to the 2-wire system, thus providing communications to and control over those devices from Acclima’s CS3500 controller.
Installation:
2/4 Zone Adapters should be installed in the valve box they can also be directly buried.
Features:
- Waterproof, submersible enclosure
- Interfaces with any 24vac solenoid valve
- Zone activity LED for each zone
- Communications activity LED
- 14 Gauge Polyethylene insulated wire
- Automatic overload and short-circuit disconnect
- Short-circuit and overload reporting to controller
Specifications
- Power Consumption (valves off): 24vac 20ma, .48w
- Load Capability per zone: 0.7 A rms
- Operating Temperature Range: -20C to 70C
- Survival Temperature Range: -40C to 85C
- 36" min wire length for 2-Wire and zone connections